CIRIA C753 §23: wet pond sizing for treatment, attenuation and biodiversity.
1
Site & Design
2
Calculate
3
Compliance
4
PDF Export
Step 1 of 4: Site & Design Parameters
Project Information
Fields marked * are required
Catchment Parameters
from site plans
m²
including soft landscape
ha
5-15mm typical, check local guidance
mm
water balance check
mm
EA May 2022 Climate Change Allowances Table 3 (surface-water peak rainfall intensity). These apply to peak-flow / attenuation storage for extreme events — they are carried by the attenuation volume you enter from Calculator 2 ("includes all return periods"). They are not applied to the water-quality treatment depth above, which sizes the permanent pool (a first-flush treatment volume per CIRIA C753 and so not climate-uplifted).
default 450mm for England
mm
if applicable, else 0
l/s
Design Requirements
These values come from Calculator 1 (Discharge Control) and Calculator 2 (Volume Estimation).
from Calculator 2, includes all return periods
m³
from Calculator 1
l/s
Pond Geometry
typical 1-2m
m
shallow margin, ≤600mm
m
2:1 to 5:1
landscape design
bank stability
shallow planting zone
m
marginal vegetation zone
mm
above maximum water level
mm
Z = horizontal per 1m vertical
affects stability
sediment settling zone
Inlet & Outlet Design
1% AEP (100yr) overflow route
restricted discharge rate
Step 2 of 4: Calculate & Review
Treatment Volume Calculation
CIRIA C753 Treatment Volume
Vt = (A_imp × d_rainfall) / 1000
Where:
• A_imp = Impervious area contributing to treatment (m²)
• d_avg = Average depth ≈ 2/3 × max depth (reasonable approximation for trapezoidal ponds with shallow safety benching at 1:3 side slopes per CIRIA C753 §23.5; shallower ponds with steeper sides approach 1/2 × max depth; adjust if your geometry differs significantly)